FG Wilson Generator Set Product Comparison

Print

< Back

P16.5-6S P16.5-1S P18-6
Minimum Rating
15.0 kVA / 15.0 kW 15.0 kVA / 15.0 kW 15.0 kVA / 15.0 kW 15.0 kVA / 15.0 kW 16.5 kVA / 13.2 kW 16.5 kVA / 13.2 kW
Maximum Rating
19.4 kVA / 19.4 kW 19.4 kVA / 19.4 kW 16.5 kVA / 16.5 kW 16.5 kVA / 16.5 kW 22.0 kVA / 17.6 kW 22.0 kVA / 17.6 kW
Emissions/Fuel Strategy
EU3a Emissions Compliant EU3a Emissions Compliant Fuel Optimised Fuel Optimised EUIIIa Emissions Compliant EUIIIa Emissions Compliant
50 Hz Prime
15.0 kVA / 15.0 kW 15.0 kVA / 15.0 kW 15.0 kVA / 15.0 kW 15.0 kVA / 15.0 kW 16.5 kVA / 13.2 kW 16.5 kVA / 13.2 kW
50 Hz Standby
16.5 kVA / 16.5 kW 16.5 kVA / 16.5 kW 16.5 kVA / 16.5 kW 16.5 kVA / 16.5 kW 18.0 kVA / 14.4 kW 18.0 kVA / 14.4 kW
60 Hz Prime
17.6 kVA / 17.6 kW 17.6 kVA / 17.6 kW - / - - / - 20.0 kVA / 16.0 kW 20.0 kVA / 16.0 kW
60 Hz Standby
19.4 kVA / 19.4 kW 19.4 kVA / 19.4 kW 22.0 kVA / 17.6 kW 22.0 kVA / 17.6 kW
Frequency
50 / 60 Hz 50 / 60 Hz 50 Hz 50 Hz 50 / 60 Hz 50 / 60 Hz
Speed
1500 or 1800 RPM 1500 or 1800 RPM 1500 RPM 1500 RPM 1500 or 1800 RPM 1500 or 1800 RPM
Voltage
220-240 Volts 220-240 Volts 220-240 Volts 220-240 Volts 220-415 Volts 220-415 Volts
50 Hz Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
60 Hz Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
50 Hz Standby Rating
Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.