< Back

Overview

The 6.8 - 25 kVA range of generator sets is designed to power your every need. Suitable for use in diverse applications including construction, residential, retail and telecommunications, this range has been redesigned for optimum performance in some of the harshest and most remote environments. Available with a metal or polymer enclosure offering, this range is designed to withstand the test of time.

Generator Set Specifications

Minimum Rating 6.8 kVA / 6.8 kW 6.8 kVA / 6.8 kW Less
Maximum Rating 7.5 kVA / 7.5 kW 7.5 kVA / 7.5 kW Less
Emissions/Fuel Strategy Fuel Optimised Fuel Optimised Less
50 Hz Prime 6.8 kVA / 6.8 kW 6.8 kVA / 6.8 kW Less
50 Hz Standby 7.5 kVA / 7.5 kW 7.5 kVA / 7.5 kW Less
60 Hz Prime - / - - / - Less
60 Hz Standby Less
Frequency 50 Hz 50 Hz Less
Speed 1500 RPM 1500 RPM Less
Voltage 230-240 Volts 230-240 Volts Less
50 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Less
60 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Less
50 Hz Standby Rating Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Less

Engine Specifications

Engine Model Perkins® 403A-11G1 Perkins® 403A-11G1 Less
Bore 77.0 mm (3.0 in) 77.0 mm (3.0 in) Less
Stroke 81.0 mm (3.2 in) 81.0 mm (3.2 in) Less
Governor Type Mechanical Mechanical Less
Displacement 1.1l (69.0 cu. in) 1.1l (69.0 cu. in) Less
Compression Ratio 23:01 23:01 Less

The Story

Industry Leading Perkins Engine

Alternator

Deep Sea DSE4520

Testing & Validation

World Wide Product Support

Cooling System

P7.5-1S Standard Equipment

Engine
  • Air Cleaner
  • Lube oil drain valve
  • Engine filled with lubrication oil
  • High Coolant Temperature Shutdown
  • Low Oil Pressure Shutdown

Cooling
  • Package mounted radiator
  • Radiator & Cooling Fan
  • Coolant Drain Valve
  • Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive
  • Cooling System filled with Coolant mix

Exhaust
  • Exhaust flange outlet
  • Exhaust stub pipe and gasket

Alternator
  • Leroy Somer
  • SHUNT Excitation
  • IP23 Protection

Control Panel
  • DeepSea 4520

Mounting
  • Skid Base, Formed Steel
  • Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets
  • Anti-vibration mounts
  • Battery Tray and Cables

P7.5-1S Optional Equipment

Exhaust
  • Industrial

Control Panels
  • Deep Sea DSE7410
  • Deep Sea DSE7420

Starting/Charging
  • Lead Acid battery (Dry)

General
  • Upgrade to Standard Set for "CE" Certification
  • EEC Declaration of Conformity
  • 8 Hour, 600L, 1000L, 2000L fuel tanks
  • Level 1, 2, 3 Sound attenuated, galvanised steel enclosure
  • Dual wall fuel tanks