< Back

Overview

The 24 - 220 kVA range provides reliable power for today's world with a competitive offering that delivers everything you need. Providing unrivalled quality, the 24 - 220 kVA range of products offers a trusted performance with an enhanced choice of options, optimising the range for a variety of diverse applications and environments. Designed with the demands of today's world in mind, this range will deliver power solutions in all sectors, from industry and retail to finance and healthcare.

Generator Set Specifications

Minimum Rating 45.0 kVA / 45.0 kW 45.0 kVA / 45.0 kW Less
Maximum Rating 60.0 kVA / 60.0 kW 60.0 kVA / 60.0 kW Less
Emissions/Fuel Strategy Fuel Optimised Fuel Optimised Less
50 Hz Prime 45.0 kVA / 45.0 kW 45.0 kVA / 45.0 kW Less
50 Hz Standby 50.0 kVA / 50.0 kW 50.0 kVA / 50.0 kW Less
60 Hz Prime 55.0 kVA / 55.0 kW 55.0 kVA / 55.0 kW Less
60 Hz Standby 60.0 kVA / 60.0 kW 60.0 kVA / 60.0 kW Less
Frequency 50 / 60 Hz 50 / 60 Hz Less
Speed 1500 or 1800 RPM 1500 or 1800 RPM Less
Voltage 110-240 Volts 110-240 Volts Less
50 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Less
60 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Less
50 Hz Standby Rating Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Less

Engine Specifications

Engine Model Perkins® 1103A-33TG2 Perkins® 1103A-33TG2 Less
Bore 105 mm (4.1 in) 105 mm (4.1 in) Less
Stroke 127 mm (5 in) 127 mm (5 in) Less
Governor Type Mechanical Mechanical Less
Displacement 3.3l (201.4 cu. in) 3.3l (201.4 cu. in) Less
Compression Ratio 17.25:1 17.25:1 Less

The Story

Industry Leading Perkins Engine

Alternator

DCP10

Testing & Validation

World Wide Product Support

P50-5S Standard Equipment

Engine
  • Air Cleaner
  • Lube oil drain valve
  • Engine filled with lubrication oil
  • High Coolant Temperature Shutdown
  • Low Oil Pressure Shutdown

Cooling
  • Package mounted radiator
  • Radiator & Cooling Fan
  • Coolant Drain Valve
  • Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive
  • Cooling System filled with Coolant mix

Exhaust
  • Exhaust flange outlet
  • Exhaust stub pipe and gasket

Fuel
  • 8 Hr Fuel Tank
  • Fuel Fittings for Local and Remote Feed

Alternator
  • Marelli
  • SHUNT Excitation
  • IP23 Protection

Control Panel
  • DCP-10

Mounting
  • Base, Formed Steel with Single wall Fuel Tank
  • Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets
  • Anti-vibration mounts
  • Battery Tray and Cables

P50-5S Optional Equipment

Exhaust
  • Industrial, Residential, Critical Silencers

Alternator
  • Upgrade to Leroy Somer Alternator
  • Quadrature Droop Kit (AR6)
  • Anti-Condensation Heater and Panel Circuitry (AH1)

Control Panels
  • PowerWizard 1.1 Control Panel (PWT1.1)
  • PowerWizard 1.1+ Control Panel (PWT1.1+)
  • PowerWizard 2.1 Control Panel (PWT2.1)

Starting/Charging
  • Lead Acid battery (Dry)

General
  • Upgrade to Standard Set for "CE" Certification
  • EEC Declaration of Conformity
  • Narrow, Wide or Skid Base
  • Sound attenuated, steel or galvanised enclosure
  • Dual wall fuel tanks